infra:tools:jbc-hd2b
Differences
This shows you the differences between two versions of the page.
| Both sides previous revisionPrevious revisionNext revision | Previous revision | ||
| infra:tools:jbc-hd2b [2025/11/06 21:02] – q3k | infra:tools:jbc-hd2b [2026/10/10 09:43] (current) – krnlexception | ||
|---|---|---|---|
| Line 6: | Line 6: | ||
| Donated by q3k after he bought a bunch from a Kleinanzeigen seller who imported them from some Romanian factory. | Donated by q3k after he bought a bunch from a Kleinanzeigen seller who imported them from some Romanian factory. | ||
| + | |||
| + | Currently broken, to be fixed or replaced. | ||
| ===== Usage ===== | ===== Usage ===== | ||
| Line 33: | Line 35: | ||
| ===== Known Issues ===== | ===== Known Issues ===== | ||
| - | *Open Circuit Error*: Seemingly a firmware bug due to the 24V modification. Put away the tool on the stand, wait for the error to clear, pick up again - the error should clear itself. q3k has started reverse engineering the firmware to fix this issue, but the MCU inside the station is a dsPIC, which does not make the effort fun. | + | **Open Circuit Error**: Seemingly a firmware bug due to the 24V modification. Put away the tool on the stand, wait for the error to clear, pick up again - the error should clear itself. q3k has started reverse engineering the firmware to fix this issue, but the MCU inside the station is a dsPIC, which does not make the effort fun. |
infra/tools/jbc-hd2b.1762462946.txt.gz · Last modified: by q3k